浅析热平衡措施对上海地区地源热泵系统换热区域温度的影响

作者:吕亮
单位:上海市地矿工程勘察集团)有限公司 上海浅层地热能发展研究中心 上海浅层地热能工程技术研究中心
摘要:基于上海地区浅层地热能项目多年的监测数据,分析了多个地源热泵项目运行多年后换热区域温度的变化特征,以及热平衡措施对换热区域温度的影响。分析结果表明:所监测地埋管地源热泵项目中,具备热平衡措施项目的地埋管换热区域温度基本稳定;不具备热平衡措施项目的地埋管换热区域温度基本上呈现升高趋势,出现了明显的热堆积现象。
关键词:地源热泵系统换热区域地温场热平衡措施热堆积监测数据
作者简介:吕亮,男,1989年生,硕士研究生,工程师200436上海市宝山区环镇南路522号地矿大厦B座6楼,E-mail:lv3675@163.com;
基金:上海市建筑建材业市场管理总站科研项目“浅层地热能应用建筑低碳运行管理与评价技术研究”(编号:沪建科2022-005-009);
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 赵民,康维斌,李杨,等.浅层地热能在常见民用建筑中的适宜性分析[J].暖通空调,2022,52(5):2- 7.

[2] 陈焰华,於仲义.从建筑碳排放达峰看地热能的技术特性[J].暖通空调,2022,52(1):75- 80.

[3] 马宏权,龙惟定.地埋管地源热泵系统的热平衡[J].暖通空调,2009,39(1):102- 106.

[4] 马最良,吕悦.地源热泵系统设计与应用[M].北京:机械工业出版社,2007:204- 205.

[5] 吕超,郑茂余.土壤源热泵系统土壤热平衡的评价方法研究[J].制冷学报,2016,37(3):42- 47.

[6] 唐益群,张墨丹.上海地源热泵应用综论[J].低温建筑技术,2011,33(7):110- 112.

[7] 刘晓茹.地埋管地源热泵系统热平衡及其地域性分析[J].暖通空调,2008,38(9):57- 59.

[8] 孙婉,周念清,黄坚,等.地源热泵系统运行换热区域内外地温场变化特征分析[J].太阳能学报,2017,38(10):2804- 2810.

[9] 吴玲红,叶大法,梁韬.上海世博轴江水源与地源热泵联合系统设计[C]//第3届中国制冷空调工程节能应用新技术研讨会,2008:65- 71.
Effect of heat balance measures on temperature in heat exchange area of ground-source heat pump systems in Shanghai
Lü Liang
(Shanghai Geological Engineering Exploration (Group) Co., Ltd. Shanghai Development Research Center for Shallow Geothermal Energy Shanghai Engineering Research Center for Shallow Geothermal Energy)
Abstract: Based on the monitoring data of shallow geothermal energy projects in Shanghai for many years, the change characteristics of the temperature field in the heat exchange area of the ground-source heat pump projects after many years of operation and the effect of thermal balance measures on the temperature field in the heat exchange area are analysed. The analysis results show that in the monitored buried pipe ground-source heat pump projects, the temperature in the buried pipe heat exchange area of the projects with heat balance measures is basically stable, that of the projects without heat balance measures basically shows an increasing trend, and obvious heat accumulation appears.
Keywords: ground-source heat pump system; heat exchange area; geothermal field; heat balance measure; heat accumulation; monitoring data;