中国人民革命军事博物馆改扩建工程暖通空调设计

作者:高刚 曹晓庆 王春香 马友才
单位:中南建筑设计院股份有限公司
摘要:该工程根据室内温湿度控制要求,对温湿度要求较高的地下文物藏品库采用恒温恒湿空调系统,展厅、办公及其辅助用房采用普通空调系统。冷热源分别设置,其中藏品库采用带部分热回收水冷冷水机组,冷凝热回收用于再热。展厅采用温湿度独立控制空调系统,独立新风系统采用全热回收型新风机组。对展厅温湿度分控系统及地下藏品库房进行了热湿负荷计算和分析,给出了恒温恒湿系统主机及末端控制策略。
关键词:博物馆地下藏品库温湿度独立控制恒温恒湿湿负荷计算
作者简介:高刚,男,1983年生,硕士研究生,高级工程师430070湖北省武汉市武昌区中南路19号中南建筑设计院机电市政中心E-mail:275345255@qq.com;
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 吴来明,徐方圆,黄河.博物馆环境监控及相关物联网技术应用需求分析[J].文物保护与考古科学,2011,23(3):96-102.

[2] 华东建筑设计研究院有限公司.博物馆建筑设计规范:JGJ 66-2015[S].北京:中国建筑工业出版社,2015:27.

[3] 中国国家标准化管理委员会.空气-空气能量回收装置:GB/T 21087-2007[S].北京:中国标准出版社,2008:5.

[4] 赵荣义,范存养,薛殿华.空气调节[M].4版.北京:中国建筑工业出版社,2009:83-91.

[5] 张辉.风机盘管干工况运行的空调系统研究[J].铁道标准设计,2010(增刊2):32-37.
HVAC system design for reconstruction project of Military Museum of the Chinese People's Revolution
Gao Gang Cao Xiaoqing Wang Chunxiang Ma Youcai
(Central-South Architectural Design Institute Co.,Ltd.)
Abstract: According to the indoor temperature and humidity control requirements, the underground artifacts collections repositories with high temperature and humidity requirements of this engineering use the constant temperature and humidity air conditioning system, and the comfortable air conditioning systems are used in the exhibition hall, office and their auxiliary rooms. The cold and heat sources are set separately, the collections repositories adopt the water cooling machine with heat recovery, and partial condensation heat recovery is used for reheating. The exhibition hall uses the temperature and humidity independent control air conditioning systems, and the independent outdoor air system uses full heat recovery type outdoor air units. This paper calculates and analyses the heat and moisture loads in the exhibition hall temperature and humidity separation system and the underground collections repositories, and gives the host and end control strategies of the constant temperature and humidity system.
Keywords: museum; underground collections repository; temperature and humidity independent control; constant temperature and humidity; moisture load calculation;
703 0 0
文字:     A-     A+     默认 取消