某8度区近断层甲类建筑基础隔震分析与设计

引用文献:

辛力 ,杨琦 ,段成刚 ,荆罡, 史生志. 某8度区近断层甲类建筑基础隔震分析与设计[J]. 建筑结构,2022,48(19):124-131.

XIN Li ,YANG Qi ,DUAN Chenggang ,JING Gang ,SHI Shengzhi. Base isolation analysis and design of a class A building near fault in 8 degree area[J]. Building Structure,2022,48(19):124-131.

作者:辛力 ,杨琦 ,段成刚 ,荆罡, 史生志
单位:中国建筑西北设计研究院有限公司
摘要:以8度区西安市疾病预防控制中心病毒实验楼为研究对象,分析了近断层地震动特性及其对隔震结构的不利影响,确定了甲类建筑基础隔震设计所需的地震动参数和抗震性能目标。对比了橡胶隔震支座、橡胶隔震支座+黏滞阻尼器、橡胶隔震支座+黏滞阻尼器+滑板隔震支座三种隔震层设计方案,研究了黏滞阻尼器和滑板隔震支座对隔震层的影响。表明黏滞阻尼器能够有效控制隔震层在大震作用下的位移。根据分析结果选择橡胶隔震支座+黏滞阻尼器+滑板隔震支座的隔震方案。上部结构分别采用直接分析法和传统水平向减震系数法相融合的设计方法进行设计,通过楼层剪力对比验证该方法的合理性。采用PERFORM 3D软件对隔震结构进行了大震作用下的抗震性能评估,结果表明结构完全满足罕遇地震可修、极罕遇地震不倒的性能目标。
关键词:8度区;近断层;甲类建筑;基础隔震;黏滞阻尼器;隔震结构;振型分解反应谱法;弹塑性分析
作者简介:辛力,博士,教授级高级工程师,一级注册结构工程师,主要从事工程抗震研究,Email:xinli1129@sina.com。史生志,硕士,高级工程师,一级注册结构工程师,注册土木工程师(岩土),主要从事结构抗震设计与研究工作,Email:shishengzhi@126.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 杨迪雄,李刚,程耿东.近断层地震动作用下隔震结构的优化设计[J].世界地震工程,2006,22(1):1-8.
[2] 王海东,刘巴黎,蔡长丰.近场水平地震动选取原则及脉冲型水平地震动弹性谱特性研究[J].地震工程与工程振动,2019,39(1):222-230.
[3] 建筑抗震设计规范:GB 50011—2010[S].2016年版.北京:中国建筑工业出版社,2016.
[4] 建筑工程抗震设防分类标准:50223—2008[S].北京:中国建筑工业出版社,2008.
[5] 金建敏,谭平,黄襄云,等.铅芯橡胶支座微分型恢复力模型屈服前刚度的研究[J].广州大学学报(自然科学版),2008,7(1):87-90.
[6] 日本建筑学会.隔震结构设计[M].北京:地震出版社,2006.
[7] 辛力,杨琦,王红群,等.某高烈度区高层框架-剪力墙结构基础隔震设计与分析[J].建筑结构,2021,51(8):8-13.
[8] 建筑隔震设计标准:GB/T 51408—2021[S].北京:中国计划出版社有限公司,2021.
[9] Prestandard and commentary for the seismic rehabilitation of buildings:FEMA 356[S].Washington,D.C.:Federal Emergency Management Agency,2000.
[10] 叠层橡胶支座隔震技术规程:CECS 126:2001[S].北京:中国工程建设标准化协会,2001.
Base isolation analysis and design of a class A building near fault in 8 degree area
XIN Li ,YANG Qi ,DUAN Chenggang ,JING Gang ,SHI Shengzhi
(China Northwest Building Design & Research Institute Co., Ltd.)
Abstract: The characteristics of near-fault ground motions and their adverse effects on isolated structures were analyzed by taking a virus laboratory building of the Xi'an Center for Disease Control and Prevention in 8 degree area as the research object. The ground motions parameters and seismic performance objectives for the base-isolated design of the class A buildings were also determined. The three seismic isolation interface design schemes were discussed including rubber seismic isolator, rubber seismic isolator + viscous damper, rubber seismic isolator + viscous damper + sliding plate seismic isolator, and the influence of viscous dampers and sliding plate seismic isolators on the seismic isolation interface was researched. The results show that the viscous dampers can effectively decrease the displacement of the seismic isolation interface under rare earthquake. According to the analysis results, the scheme of rubber seismic isolator + viscous dampers + sliding plate seismic isolator was adopted. The combination of direct analysis method and traditional horizontal damping coefficient method was adopted for the design of the upper structure. The rationality of this method was verified by comparing the inter-story shear force of floor. The seismic performance of the isolated structure was evaluated using the PERFORM 3 D software. The results that the structures fully satisfy repairable under rare earthquake and no collapse during very rare earthquake.
Keywords: 8 degree area; near-fault; class A building; base isolation; viscous damper; seismic isolation structure; mode response spectrum method; elastoplastic analysis