摘要:对规范中抗液化措施的适用性进行了讨论,指出了现有基于震陷量的抗液化研究的不足。提出了考虑场地液化等级、差异震陷引起的局部倾斜、建筑抗震设防类别的抗液化法,提出了局部倾斜控制值Tk。用有限元法分析了差异震陷对楼层侧移和构件内力的影响,结果表明,框架结构达到中等破坏对应的局部倾斜约0.009 2,剪力墙结构达到中等破坏对应的局部倾斜约0.007 7,与局部倾斜控制值较为吻合。介绍了抗液化法在某不均匀液化场地的工程应用,通过计算差异震陷,对不同楼栋采取了不同的抗液化措施,并对地基处理方案进行了比较和优化,弥补了规范关于不均匀液化场地选取抗液化措施的不足,可供其他项目参考。
关键词:不均匀液化场地;差异震陷;局部倾斜;抗液化设计
作者简介:章钢雷,硕士,高级工程师,主要从事建筑结构设计工作,Email:446725125@qq.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑抗震设计规范:GB 50011—2010[S].2016年版.北京:中国建筑工业出版社,2016.
[2] 朱炳寅.建筑抗震设计规范应用与分析[M].北京:中国建筑工业出版社,2011.
[3] 谢君斐,石兆吉,郁寿松,等.液化危害性分析[J].地震工程与工程振动,1988,8(1):61-77.
[4] 石兆吉,张克绪,谢君斐.液化土层上多层砖房震害预测方法的研究[J].地震工程与工程震动,1992,12(2):39-47.
[5] 丰万玲,石兆吉.判别水平土层液化势的孔隙水压力分析方法[J].工程抗震,1988(4):30-33.
[6] 孙锐,袁晓铭.液化土层地震动模拟计算方法及验证[J].岩土力学,2007,28(S1):759-764.
[7] 孟上九,袁晓铭.建筑物不均匀震陷简化分析方法[J].地震工程与工程振动,2003,23(2):102-107.
[8] 刘惠珊.预估液化震陷的经验公式[C]//第三届全国土动力学学术会议论文集.杭州,1994.
[9] 刘惠珊.预估液化震陷经验公式再探讨[J].工程抗震,1997(4):34-37.
[10] 石兆吉,张荣祥,孙锐.液化土层隔震和地基失效共同作用下多层砖房震害分析[J].自然灾害学报,1995,4(1):55-62.
[11] 张荣祥,顾宝和,汪敏,等.建筑场地地震液化危害评价及地基处理[J].工程地质学报,1998,6(3):205-210.
[12] 任景敏.计算建筑震陷量在液化场地中的应用[J].山西建筑,2019,45(6):50-51.
[13] 李巍,王泰钦,阴伟华.严重液化场地单层建筑地基基础的选型及分析[J].工程质量,2013,31(5):21-23.
[14] 王素萍.多层建筑严重液化场地地基基础设计分析[J].规划与设计,2019,(28):125-126.
[15] 建筑地基基础设计规范:GB 50007—2011[S].北京:中国建筑工业出版社,2011.
[16] 危险房屋鉴定标准:JGJ 125—2016[S].北京:中国建筑工业出版社,2016.
Research and applications of anti-liquefaction design considering differential seismic subsidence for uneven liquefaction site
ZHANG Ganglei ,WU Yingdong ,YE Anjie
(gad·Zhejiang Greenton Architectural Design Co.,Ltd.)
Abstract: The applicability of anti-liquefaction measures in codes was discussed, the deficiencies of existing anti-liquefaction study based on seismic subsidence was pointed out. An anti-liquefaction measure considering site liquefaction grade, local tilt caused by differential seismic subsidence, seismic fortification category of buildings was presented, and the controlled value of local tilt Tk was suggested. The influence of differential seismic subsidence on the displacement of floor and the internal force of components was analyzed by finite element method, the results show that the local tilt corresponding to the moderate failure of frame structure is about 0.009 2, the local tilt corresponding to the moderate failure of shear wall structure is about 0.007 7,which match the controlled value of local tilt roughly. The engineering application of anti-liquefaction method in an uneven liquefaction site was introduced, different anti-liquefaction measures were taken in different buildings by calculating differential seismic subsidence, foundation treatment schemes were compared and optimized. It makes up for the deficiencies in the specification regarding the selection of anti-liquefaction measures for uneven liquefaction sites, and can be used as a reference for other projects.