带有盖板的H型钢梁柱弱轴连接节点试验及有限元分析

引用文献:

苏磊 ,曹志亮, 林海鹏 ,刘步芳. 带有盖板的H型钢梁柱弱轴连接节点试验及有限元分析[J]. 建筑结构,2022,48(19):98-104.

SU Lei ,CAO Zhiliang, LIN Haipeng ,LIU Bufang. Test and finite element analysis on H-shaped steel beam-to-column connection with cover plate in the weak axis[J]. Building Structure,2022,48(19):98-104.

作者:苏磊 ,曹志亮, 林海鹏 ,刘步芳
单位:北京市住宅产业化集团股份有限公司, 北京建谊投资发展集团)有限公司 ,中国建筑科学研究院有限公司
摘要:为研究H型钢梁柱的弱轴连接节点的性能,对有盖板的H型钢梁柱弱轴连接节点以及梁柱是否偏心节点进行了试验研究和有限元校核模拟,并对8组盖板参数不同的梁柱连接节点的受力性能进行有限元分析。研究结果表明:无偏心和偏心弱轴连接节点的试验现象分别为梁翼缘至腹板的开裂和悬臂梁段的平面外失稳;有限元的分析结果与试验结果吻合较好,能够正确反映节点的受力情况;盖板的高度能够一定程度地加强节点的初始转动刚度;盖板能够明显改善钢柱节点域的局部应力集中,加强节点的刚度,并提升柱的屈服承载力;偏心弱轴连接节点在有、无盖板的情况下可分别视作刚性连接节点和半刚性连接节点;盖板的设置能够显著地提升节点的转动刚度和耗能能力。
关键词:H型钢梁柱节点;弱轴加盖板;弱轴连接节点;偏心节点;受力性能
作者简介:苏磊,博士,高级工程师,主要从事钢结构领域的设计工作,Email:sageyou@163.com。曹志亮,硕士,高级工程师,主要从事钢结构领域的设计工作,Email:caozhiliang@bjjy.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] MILLER D K.Lessons learned from the Northridge earthquake[J].Engineering Structures,1998,20(4/5/6):249-260.
[2] GILTON C S,UANG C M.Cyclic response and design recommendations of weak-axis reduced beam section moment connections[J].Journal of Structural Engineering,2002,128(4):452-463.
[3] KOETAKA Y,CHUSILP P,ZHANG Z J,et al.Mechanical property of beam-to-column moment connection with hysteretic dampers for column weak axis[J].Engineering Structures,2005,27(1):109-117.
[4] KIM S D,KIM S S,JU Y K.Strength evaluation of beam-column connection in the weak axis of H-shaped column[J].Engineering Structures,2008,30(6):1699-1710.
[5] 孙玉萍,聂李平,王万祯,等.梁柱弱轴螺栓拼接节点性能分析[J].甘肃科学学报,2009,21(2):129-133.
[6] 孙玉萍,王云,王万祯,等.弱轴连接的梁柱狗骨式节点性能研究[J].四川建筑科学研究,2009,35(3):17-20.
[7] 卢林枫,徐莹璐,周天华,等.H形梁-工形柱弱轴箱形节点域连接节点单调加载试验研究[J].建筑结构学报,2016,37(2):73-80.
[8] 钢结构高强度螺栓连接技术规程:JGJ 82—2011[S].北京:中国建筑工业出版社,2011.
[9] 钢结构设计标准:GB 50017—2017[S].北京:中国建筑工业出版社,2018.
[10] 建筑抗震试验规程:JGJ/T 101—2015[S].北京:中国建筑工业出版社,2015.
[11] Eurocode 3:design of steel structures-part 1-8:design of joints:EN 1993-1-8 [S].Brussels:European Committee for Electrotechnical Normalization,2003.
Test and finite element analysis on H-shaped steel beam-to-column connection with cover plate in the weak axis
SU Lei ,CAO Zhiliang, LIN Haipeng ,LIU Bufang
(Beijing Building Industrialization Group Co., Ltd. Beijing Jianyi Investment Development(Group) Co., Ltd. China Academy of Building Research)
Abstract: In order to explore the mechanic performance of H-shaped steel beam-to-column connection in the weak axis, the eccentricity and non-eccentricity of H-shaped steel beam-to-column connection with cover plate in the weak axis were studied by testing and numericial simulation, in which case the finite element analysis in 8 gourps of the beam-to-column connections with different parameters at cover plate was conducted for mechanical performance research. The results show that: the experimental phenomena of the eccentricity and non-eccentricity connection were the cracks from the flange to the web and the out-of-plane instability of the cantilever beam segment; the finite element analysis results are in good agreement with the experimental results, which can correctly reflect the mechanical performance of connections; the height of the cover plate can strengthen the initial rotational stiffness of the connection to a small extent; the cover plate can significantly alleviate stress concentration problem in panel zone, enhance the stiffness of the connection and the yield capacity of the column; the eccentric connection in weak axis with and without cover plate shall be regarded as rigid connection and semi-rigid connection respectively; the installation of cover plate can obviously improve rotational stiffness and the energy dissipation capacity.
Keywords: H-shaped steel beam-to-column connection; the cover plate in weak axis; connection node in weak axis; eccentricity node; mechanical performance
359 0 0
文字:     A-     A+     默认 取消