双向退台“悬空”建筑结构设计及关键技术研究

引用文献:

张伟 郑茜 张佳琳 田启祥 洪欣. 双向退台“悬空”建筑结构设计及关键技术研究[J]. 建筑结构,2023,48(09):59-66,74.

ZHANG Wei ZHENG Qian ZHANG Jialin TIAN Qixiang HONG Xin. Research on structural design and key technology of suspended building with two-way retraction[J]. Building Structure,2023,48(09):59-66,74.

作者:张伟 郑茜 张佳琳 田启祥 洪欣
单位:中建科技集团有限公司
摘要:宕口酒店依山而建,位于旧有采石场开挖后遗存台地。建筑正立面呈双向退台造型,与后方山体轮廓线基本保持一致。主塔楼以7层为界,上下两组楼层分别呈南北和东西向布置,总体呈T形平面。利用楼电梯间隔墙设置5个钢筋混凝土筒体,构建“多塔+连体+长悬臂”的框架-剪力墙结构。针对塔楼整体性偏弱特点,合理设置抗震缝以简化结构体系;东西侧端跨各增设一段联肢墙,增强整体抗扭刚度;增加走廊区域楼板宽度;调整筒体内楼梯间布置,以实现东西向框架梁得以贯通设置;位于7层错层区域改为坡屋面等,以上措施能实现弱化平面和立面布置的不规则程度,增强塔楼整体性的综合效应。计算分析表明,靠近端跨的筒体对抗扭刚度贡献起控制性作用。大震弹塑性对比分析表明,位于后方山体边跨柱底设置隔震支座对降低框架柱损伤程度有明显作用,且对相邻墙肢损伤影响程度有限。
关键词:平面不规则;长悬臂;多塔;连体;框架-剪力墙结构;空腹桁架;山地建筑;隔震;
作者简介:张伟,硕士,正高级工程师,一级注册结构工程师,主要从事高层建筑和装配式建筑设计与研究工作,Email:593225626@qq.com。
基金:中建科技集团有限公司科技研发计划资助(ZJKJ-2022-3)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[2] 中国地震动参数区划图:GB 18306—2015[S].北京:中国标准出版社,2016.
[3] 建筑抗震设计规范:GB 50011—2010[S].2016年版.北京:中国建筑工业出版社,2016.
[4] 宕口酒店岩土工程勘察报告(详细勘察)[R].徐州:徐州中国矿大岩土工程新技术发展有限公司,2020.
[5] 超限高层建筑工程抗震设防专项审查技术要点:建质[2010]109号[A].北京:中华人民共和国住房和城乡建设部,2015.
[6] 徐州宕口酒店项目超限高层建筑抗震设防专项审查可行性报告[R].深圳:中建科技集团有限公司,2020.
[7] 混凝土结构设计规范:GB 50010—2010[S].2015年版.北京:中国建筑工业出版社,2015.
[8] 建筑隔震橡胶支座:JG/T 118—2018[S].北京:中国标准出版社,2018.
[9] 建筑隔震设计标准:GB/T 51408—2021[S].北京:中国计划出版社,2021.
Research on structural design and key technology of suspended building with two-way retraction
ZHANG Wei ZHENG Qian ZHANG Jialin TIAN Qixiang HONG Xin
(China Construction Technology Group Co., Ltd.)
Abstract: The quarry hotel built along the mountain is located on the platform left after the excavation of the old quarry. The front elevation of the building is two-way retreation, and it is consistent with the contour line of the mountain behind. The main tower is bounded by 7 floors, the upper and lower groups of floors are arranged in north-south and east-west directions respectively, and generally in a T-shaped plane. Five reinforced concrete cylinders are set in the partition wall of the elevator lobby of the building, the frame shear wall structure based on ‘multi tower + connected body + long cantilever' is constructed. Based on the weak integrity of the tower, the structure system was simplified by setting the anti-seismic joint reasonably, a section of coupling wall was set at the east and west end spans to enhance the overall torsional rigidity, the floor width of the corridor area was increased, the arrangement of staircase inside cylinder was adjusted to realize, the frame beams arranged in the east-west direction can be connected and set up, the staggered area located of the 7th floor was changed to sloping roof, the above measures can achieve a comprehensive effect of weakening the irregularity of plane and facade layout, and enhancing the overall integrity of the tower. The calculation and analysis show that the tube near the end span plays a controlling role in the contribution of torsional stiffness. The elastic-plastic comparative analysis under rare earthquakes shows that setting isolation bearing at the column bottom of the mountain side span has an obvious effect on reducing the damage degree of the frame column, and has a limited impact on the damage degree of the adjacent wall limb.
Keywords: plane irregularity; long cantilever; multi tower; connected body; frame shear wall structure; vierendeel truss; mountain architecture; isolation
512 0 0