某超限高层办公楼结构设计要点与抗震性能分析

引用文献:

闰淼 陈焰周 熊森 蔡红超 邹杰 鲁伟 丁梦阳. 某超限高层办公楼结构设计要点与抗震性能分析[J]. 建筑结构,2023,48(09):32-39,24.

RUN Miao CHEN Yanzhou XIONG Sen CAI Hongchao ZOU Jie LU Wei DING Mengyang. Structural design points and performance-based seismic analysis of an out-of-code high-rise office building[J]. Building Structure,2023,48(09):32-39,24.

作者:闰淼 陈焰周 熊森 蔡红超 邹杰 鲁伟 丁梦阳
单位:中南建筑设计院股份有限公司
摘要:某高层办公楼建筑高度为249.70m,为超B级超限高层建筑,同时有多项不规则,采用钢筋混凝土框架-核心筒结构,采用地下室外墙与基坑支护地下连续墙合为一体的两墙合一方案。风洞试验表明,风荷载为非控制工况,地震作用为控制工况。采用基于性能的抗震设计方法,进行了不同地震水准作用下的结构弹性和弹塑性分析,采取了有针对性的抗震加强措施,减少因超限和其他不规则性所带来的抗震不利影响。对结构进行了有针对性的专项分析,包括楼板应力分析,连梁支撑楼面梁解决方案分析,穿层柱屈曲分析,施工模拟分析,抗连续倒塌分析。分析结果表明,本工程能够达到预期的抗震性能目标C。各项结果均满足规范要求。
关键词:超限高层结构;结构设计;风洞试验;抗震性能分析;弹塑性分析;
作者简介:闰淼,硕士,高级工程师,一级注册结构工程师,主要从事结构设计相关工作,Email:251384529@qq.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑抗震设计规范:GB 50011—2010[S].2016年版,北京:中国建筑工业出版社,2016.
[2] 三镇中心项目4#楼工程场地地震安全性评价报告[R].武汉:武汉地震工程研究院有限公司,2021.
[3] 中国地震动参数区划图:GB 18306—2015 [S].北京:中国标准出版社,2016.
[4] 三镇中心项目4#办公楼超限高层建筑工程抗震设防可行性论证报告[R].武汉:中南建筑设计院股份有限公司,2021.
[5] 陈晓强,李霆,李宏胜,等.华电集团华中总部基地结构设计[J].建筑结构,2020,50(8):57-63.
[6] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[7] 三镇中心项目风洞试验与抗风性能分析项目报告书(4#楼)[R].武汉:武汉大学结构风工程研究所,2021.
[8] 李霆,张慎,刘沛林,等.一种可以支承楼面梁的分段式钢筋混凝土连梁:CN204781592U[P].2015-11-18.
[9] 李霆,张慎,王杰,等.钢筋混凝土分段式连梁抗震性能分析及应用[J].建筑结构,2016,46(13):90-96.
[10] 建筑结构抗倒塌设计规范:CECS 392:2014[S].北京:中国计划出版社,2015.
[11] 张军朋,方先慧.循环荷载作用下SFRC/RC组合柱抗震性能研究[J].施工技术(中英文),2022,51(9):9-14.
Structural design points and performance-based seismic analysis of an out-of-code high-rise office building
RUN Miao CHEN Yanzhou XIONG Sen CAI Hongchao ZOU Jie LU Wei DING Mengyang
(Central-South Architectural Design Institute Co., Ltd.)
Abstract: The building height of a high-rise office building is 249.70m, which is a super B super high-rise building, at the same time, there are many irregularities, and the reinforced concrete frame-core tube structure is adopted, and the two-wall integration plan of combining the basement exterior wall and the foundation pit support diaphragm wall is adopted. The wind tunnel test shows that the wind load is uncontrolled condition and the seismic action is controlled condition. The performance-based seismic design method was adopted to analyze the structure's elasticity and elastic-plasticity under the action of different seismic levels, and targeted seismic strengthening measures were taken to reduce the seismic adverse effects caused by out-of-code and other irregularities. Special targeted analysis were carried out for the structure, including floor stress analysis, floor beam solution analysis supported by coupling beams, buckling analysis of columns through floors, construction simulation analysis, and continuous collapse resistance analysis. The analysis results show that the project can achieve the expected seismic performance target C. All results meet the code requirements.
Keywords: out-of-code high-rise structure; structural design; wind tunnel test; performance-based seismic analysis; elastoplastic analysis
501 0 0
文字:     A-     A+     默认 取消