珠海某超高层办公楼结构选型及设计

引用文献:

宋宝东 肖金 李巨民 张亮. 珠海某超高层办公楼结构选型及设计[J]. 建筑结构,2023,48(04):58-62,51.

SONG Baodong XIAO Jin LI Jumin ZHANG Liang. Structural scheme and design of a super high-rise office building in Zhuhai[J]. Building Structure,2023,48(04):58-62,51.

作者:宋宝东 肖金 李巨民 张亮
单位:深圳市博万结构设计事务所 珠海市建筑设计院
摘要:本工程属于超高层建筑,基于概念设计理念,根据抗震原则及建筑特点,对比分析了几种结构方案的抗侧刚度效率及工程经济性指标,最终选取了不带加强层的型钢混凝土柱钢筋混凝土框架-核心筒的结构体系。抗震设计中采用性能化设计方法,采用多种软件对结构进行弹性、弹塑性计算,并根据计算结果对关键和重要构件的抗震性能进行了验算。结果表明,结构各项指标均满足规范要求,结构受力合理,整个体系具有良好的抗震性能和有效的耗能机制。
关键词:超高层建筑;框架-核心筒结构;结构选型;抗震性能化设计;动力弹塑性时程分析;
作者简介:宋宝东,学士,高级工程师,一级注册结构工程师,主要从事超高层建筑结构设计研究,Email:jlsbd@126.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑工程抗震设防分类标准:GB 50223-2008[S].北京:中国建筑工业出版社,2012.
[2] 建筑结构荷载规范:GB 50009-2012[S].北京:中国建筑工业出版社,2012.
[3] 井彦青,丁相飞,赵俊沂,等.日照华润中心塔楼超限高层结构设计[J].建筑结构,2019,49(12):13-18.
[4] 张良平,杨文参.某超高层建筑结构设计中几个关键问题的思考[J].建筑结构,2019,49(7):56-61.
[5] 黄昌靛,李志强,杨石,等.华润前海中心钢管混凝土叠合柱应用探讨[J].建筑结构,2019,49(10):41-45.
[6] 钢管混凝土叠合柱结构技术规程:CECS 188:2005[S].北京:中国计划出版社,2005.
[7] 高层建筑混凝土结构技术规程:JGJ 3-2010[S].北京:中国建筑工业出版社,2011.
[8] 建筑抗震设计规范:GB 50011-2010[S].2016年版.北京:中国建筑工业出版社,2016.
[9] 超限高层建筑工程抗震设防专项审查技术要点:建质[2015]67号[A].北京:中华人民共和国住房和城乡建设部,2015.
[10] 四川省抗震设防超限高层民用建筑工程界定标准:DB51/T 5058-2020[S].成都:西南交通大学出版社,2021.
Structural scheme and design of a super high-rise office building in Zhuhai
SONG Baodong XIAO Jin LI Jumin ZHANG Liang
(Bowan Consult.Eng,Shenzhen Zhuhai Architectural Design Institute)
Abstract: This project is a super high-rise building. Based on the concept of design, according to the seismic principle and building characteristics, the lateral stiffness efficiency and engineering economic index of several structural schemes were compared and analyzed. Finally, the structural system of steel reinforced concrete frame-core tube without strengthening story was adopted. The performance design method was adopted in the seismic design, and a variety of software was used to calculate the elasticity and elastic-plastic of the structure, and the seismic performance of the key and important components was checked according to the calculation results. The results show the indexes of the structure meet the requirements of the code, and the structural design is reasonable. The whole system has good seismic performance and effective energy dissipation mechanism.
Keywords: super high-rise building; frame-core tube structure; structure selection; performance-based seismic design; dynamic elastic-plastic time history analysis