杭州亚运会足球场黄龙体育中心主体育场改造设计

引用文献:

卢云军 焦俭 杨学林 陈伟伟 陈思未 彭佳成. 杭州亚运会足球场黄龙体育中心主体育场改造设计[J]. 建筑结构,2022,48(15):85-90,109.

LU Yunjun JIAO Jian YANG Xuelin CHEN Weiwei CHEN Siwei PENG Jiacheng. Reconstruction design of Huanglong Sports Center main stadium for Asian Games Hangzhou football field[J]. Building Structure,2022,48(15):85-90,109.

作者:卢云军 焦俭 杨学林 陈伟伟 陈思未 彭佳成
单位:浙江省建筑设计研究院
摘要:浙江省黄龙体育中心主体育场为承担亚运功能的重要体育建筑,为满足亚运会足球赛事的各项要求,对其进行整体更新改造。介绍了主体育场更新改造的总体思路并进行了抗震性能化分析,分析结果表明,主体结构能满足抗震设防烈度7度、设计使用年限30年的抗震性能要求;采用频率振动法实测了斜拉索的索力,结果表明索力都有一定程度的损失。按实际索力对钢屋盖进行分析,分析结果表明目前的索力损失不影响结构安全;对屋面板翻新改造过程进行受力分析和施工监测,分析结果表明屋面结构受力与变形均在容许范围之内,可以满足各项要求。
关键词:杭州亚运会;黄龙体育中心主体育场;加固改造;抗震性能;斜拉索;频率振动法;屋面翻新
作者简介:卢云军,硕士,高级工程师,一级注册结构工程师,主要从事结构设计,Email:332657855@qq.com。焦俭,学士,正高级工程师,一级注册结构工程师,主要从事设计管理,Email:460695040@qq.com。
基金:浙江省建筑设计研究院科研项目(2021K10)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 程绍革.大型公共建筑加固改造若干问题的思考[J].建筑结构,2021,51(17):91-97.
[2] KIM B H,PARK T.Estimation of cable tension force using the frequency-based system identification method[J].Journal of Sound and Vibration,2007,304(3~5):660-676.
[3] 唐盛华,方志.考虑中间支撑的拉索等效索长计算方法[J].振动与冲击,2013,32(7):82-87.
[4] 浙江大学.黄龙体育中心主体育场钢结构检测评估报告[R].杭州,2020.
[5] 卢云军,胡世强,李江波,等.义乌之心城市生活广场超长商业结构关键问题分析[J].建筑结构,2017,47(11):101-105.
[6] 滕军,卢云军,朱焰煌.大跨空间钢结构模态频率的温度影响监测与分析[J].工程抗震与加固改造,2010,32(3):36-41.
[7] 任伟新,胡卫华,林友勤.斜拉索模态试验参数研究[J].实验力学,2005,20(1):102-108.
[8] 北京大学湍流研究国家重点实验室、中国建筑科学研究院建筑结构研究所.浙江省黄龙体育中心主体育场挑篷风荷载及内场风环境模拟实验研究[R].北京,1996.
[9] 中国建筑科学研究院建筑结构研究所.浙江省黄龙体育中心主体育场挑篷结构整体分析计算[R].北京,1998.
[10] 柳州欧维姆工程有限公司.浙江省黄龙体育中心改造项目斜拉索体系维护施工方案[R].柳州,2020.
Reconstruction design of Huanglong Sports Center main stadium for Asian Games Hangzhou football field
LU Yunjun JIAO Jian YANG Xuelin CHEN Weiwei CHEN Siwei PENG Jiacheng
(Zhejiang Province Institute of Architectural Design and Research)
Abstract: The main stadium of Zhejiang Huanglong Sports Center is an important sports building to undertake the functions of the Asian Games. In order to meet the requirements of the Asian Games football matches, reconstruction of overall structure has been achieved. The overall idea of reconstruction of main stadium was introduced, and the analysis of seismic performance was achieved. The analysis results show that the overall structure can meets the seismic performance requirements of seismic fortification intensity of 7 degrees and design service of 30 years. The cable forces of stay cables were measured by frequency vibration method, and the results show that the cable forces are reduced. According to the actual cable force, the steel roof was analyzed. The analysis results show that the current cable force attenuation does not affect the structural safety. The stress analysis and construction monitoring were carried out during the renovation of the roof slab. The analysis results show that the stress and deformation of the roof structure are within the allowable range, which can meet various requirement.
Keywords: Asian Games Hangzhou; Huanglong Sports Center main stadium; reinforcement and reconstruction; seismic performance; stay cable; frequency vibration method; roof renovation
279 0 0
文字:     A-     A+     默认 取消