某综合体酒店超高层塔楼结构设计

引用文献:

张杜 ,袁雪芬, 李昌平. 某综合体酒店超高层塔楼结构设计[J]. 建筑结构,2022,48(07):13-17.

ZHANG Du, YUAN Xuefen ,LI Changping. Structural design of a complex hotel super high-rise tower[J]. Building Structure,2022,48(07):13-17.

作者:张杜 ,袁雪芬, 李昌平
单位:启迪设计集团股份有限公司
摘要:某综合体酒店为高度150m的超限高层结构,存在两项平面不规则及刚度突变一项竖向不规则。针对平面不规则,对开洞楼板周边予以加强,补充两种不同程序计算复核;对设备夹层等层高较低的楼层,可采用二次结构与主体结构脱开处理,避免软弱层和薄弱层同时出现,同时对因刚度突变的薄弱层地震剪力放大1.25倍,设置抗震性能化目标,补充小震弹性动力时程分析和大震动力弹塑性时程分析,使结构满足抗震性能目标要求。对塔楼屋面支撑幕墙钢构架应考虑风载作用及鞭梢效应,并在整体建模中考虑钢构架与主体结构共同受力,保证钢构架具有足够的安全能力。
关键词:超限高层结构,平面及竖向不规则,薄弱层,抗震性能,鞭梢效应
作者简介:张杜,硕士,正高级工程师,一级注册结构工程师,主要从事结构设计研究,Email:du.zhang@siad-c.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑地基基础设计规范:GB 50007—2011[S].北京:中国建筑工业出版社,2011.
[2] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2010.
[3] 建筑抗震设计规范:GB 50011—2010[S].2015年版.北京:中国建筑工业出版社,2015.
[4] 钢结构设计标准:GB 50017—2017[S].北京:中国建筑工业出版社,2018.
[5] 苏州丰隆城市中心工程场地地震安全性评价报告[R].南京:江苏省地震工程研究院,2013.
[6] 超限高层建筑工程抗震设防专项审查技术要点:建质[2015]67号[A].北京:中华人民共和国住房和城乡建设部,2015.
[7] 魏琏,王森.中国建筑结构抗震设计方法发展和若干问题分析[J].建筑结构,2017,47(1):1-9.
[8] 宋鸿誉,张敏,罗强.苏州港口发展大厦结构设计与分析[J].建筑结构,2017,47(20):25-29.
[9] 傅学怡.实用高层建筑结构设计[M].北京:中国建筑工业出版社,2013.
Structural design of a complex hotel super high-rise tower
ZHANG Du, YUAN Xuefen ,LI Changping
(Tus-Design Group Co., Ltd.)
Abstract: The complex hotel is an over-limited high-rise structure with a height of 150 m. There are two plane irregularities and one vertical irregularity with sudden stiffness. In view of the plane irregularity, the periphery of the open floor slab was strengthened, and two different programs were added for calculation and review. For the floors with lower heights such as equipment mezzanine, the secondary structure can be separated from the main structure to avoid the simultaneous occurrence of weak floors. At the same time, the seismic shear force of the weak floors due to the sudden change in stiffness was amplified by 1.25 times, and the seismic performance target was set, the elastic-dynamic time-history analysis under small earthquakes and the elastic-plastic time-history analysis under large earthquakes were supplemented, so that the structure has the established seismic performance. For the steel frame of the tower roof supporting the curtain wall, the wind load and the whiplash effect should be considered, and the joint force of the steel frame and the main structure should be considered in the overall modeling to ensure that the steel frame has sufficient safety capability.
Keywords: over-limited high-rise structure; plane and vertical irregularity; weak floor; seismic performance; whiplash effect
464 0 0
文字:     A-     A+     默认 取消