摘要:中南大学湘雅医院新院区主体结构采用带转换层的钢筋混凝土框架-剪力墙结构体系,存在扭转不规则、平面凹凸不规则、刚度突变和尺寸突变、构件间断以及局部穿层柱等5项超限情况。针对结构的超限情况,结构设计制定了合理可靠的性能化设计目标,采取多项加强措施以提高重要构件及节点的设计标准,并采用多种计算软件对结构进行小震弹性分析、等效中震分析和大震动力弹塑性时程分析。结果表明,结构体系布置合理,具有良好的抗震性能,结构整体指标、关键构件和一般构件均能满足预设的抗震性能目标。
关键词:医疗建筑;超限结构;结构转换层;抗震性能化设计;大跨转换桁架;
作者简介:孙昱,学士,高级工程师,主要从事结构、BIM及数字化设计领域研究工作,Email:32269311@qq.com。
基金:医疗建筑标准化模块设计研究(KY0300-0000-2019-0010)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[2] 建筑抗震设计规范:GB 50011—2010[S].北京:中国建筑工业出版社,2010.
[3] 超限高层建筑工程抗震设防专项审查技术要点:建质[2015]67号[A].北京:中华人民共和国住房和城乡建设部,2015.
[4] 张晔.上海市第一人民医院新建医疗综合楼结构设计[J].建筑结构,2016,46(1):71-74,81.
[5] 何相宇,陈越,周岩.厦门某医院门急诊综合大楼结构设计[J].建筑结构,2018,48(S1):139-142.
[6] 朱丹,许庆,李劲龙,等.天津某大型医院门急诊医技综合楼及1号住院楼结构设计[J].建筑结构,2020,50(S1):180-187.
[7] 杨溥,李英民,赖明.结构时程分析法输入地震波的选择控制指标[J].土木工程学报,2000,33(6):33-37.
[8] 王世玉,丁洁民,吴宏磊,等.复杂建筑结构竖向荷载传递工程实例分析[J].建筑结构学报,2020,41(S2):365-373,381.
[9] 王震,杨学林,林可瑶,等.某医院行政楼高位桁架转换结构体系设计[J].建筑结构,2020,50(3):13-19.
[10] 陈凯,季跃.上汽通用设计与研发中心工程技术大楼超限高层结构设计[J].建筑结构,2021,51(S1):113-119.
Over-limit structure design of the Xiangya Hospital New Campus of Central South University
SUN Yu GONG Lingli WANG Shigao MAO Jianyu TANG Chunchao
(Hunan Architectural Design Institute Group Co., Ltd.)
Abstract: The main structure of Xiangya Hospital New Campus of Central South University adopts a reinforced concrete frame-shear wall structure system with a conversion layer, which has five over-limit conditions, such as torsional irregularity, plane concave and convex irregularity, sudden change of stiffness and size, discontinuous member and partial through-layer columns. In view of the over-limit conditions of the structure, a reasonable and reliable performance-based design goal was established, and a number of strengthening measures were taken to improve the design standards of important components and nodes. A variety of calculation softwares were used to analyze the structure for small earthquake elastic analysis, equivalent moderate earthquake analysis and large earthquake dynamic elastic-plastic time history analysis. The results show that the structural system is reasonably arranged and has good seismic performance, and the overall index of the structure, key members and general members can meet the preset seismic performance target.
Keywords: medical building; over-limit structure; structural conversion layer; performance-based seismic design; long-span transfer truss