单位:中国中元国际工程有限公司
摘要:海口双子塔-南塔结构体系外侧为巨型钢管混凝土柱+钢支撑框架,内部为钢板混凝土核心筒,二者之间为钢结构组合楼盖,需进行抗火设计。采用临界温度法对结构进行抗火设计,基于抗火设计结果建立热-固耦合整体结构模型,继而进行抗火灾连续倒塌分析。分析时考虑了高温下构件材料的刚度、屈服强度等折减以及构件的温度应力,同时对耐火极限后的构件损坏进行了评价。结果表明,采用临界温度法抗火设计以及基于整体结构的火灾全过程分析,基本可实现建筑结构在火灾时的抗连续倒塌设计目标,其中大跨组合钢次梁为防连续倒塌薄弱构件,转换梁及钢结构节点需进行防火加强。
关键词:海口双子塔抗火设计;临界温度法;热-固耦合结构模型;抗火灾连续倒塌;构件损坏评价
作者简介:罗佑新,硕士,高级工程师,一级注册结构工程师,主要从事结构设计工作,Email:luoyouxin@ippr.net。张同亿,博士,教授级高级工程师,一级注册结构工程师,主要从事复杂结构设计研究,Email:zhangtongyi@ippr.net。
基金:企业横向科研基金项目(S2016032T)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑设计防火规范:GB 50016—2014[S].北京:中国计划出版社,2014.
[2] 建筑结构抗连续倒塌设计规范:CECS 392:2014[S].北京:中国计划出版社,2014.
[3] 王宁,张同亿,张松,等.海口双子塔-南塔结构抗连续倒塌分析[J].建筑结构,2022,52(16):1-6.
[4] 张松,张同亿,王宁,等.海口双子塔-南塔结构整体稳定与关键构件计算长度系数研究[J].建筑结构,2022,52(16):7-10,21.
[5] 张特,张同亿,张松,等.海口双子塔-南塔核心筒设计与研究[J].建筑结构,2022,52(16):11-16.
[6] 张松,张同亿,王宁,等.海口双子塔-南塔折线型腰桁架设计研究[J].建筑结构,2022,52(16):22-25,6.
[7] 王宁,张同亿,肖自强,等.海口双子塔-南塔桩-筏基础设计与研究[J].建筑结构,2022,52(16):26-31,66.
[8] 李国强.钢结构及钢-混凝土组合结构抗火设计[M].北京:中国建筑工业出版社,2006.
[9] 建筑钢结构防火技术规范:GB 51249—2017[S].北京:中国计划出版社,2017.
Fire resistance design of steel structure in Haikou Twin Towers-South Tower
LUO Youxin ZHANG Tongyi WANG Ning ZHANG Song
(China IPPR International Engineering Co., Ltd.)
Abstract: The Haikou Twin Towers-South Tower adopts the structural system of giant concrete-filled steel tubular column + steel braced frame on the outside, as well as a steel plate concrete corewall inside. There is steel structure composite floor between the frame and corewall. Fire resistance design was needed. The critical temperature method was used to design the structure for fire resistance design. Based on the results of the fire resistance design, a thermal-solid coupled integral structure model was established, and then the anti-progressive collapse analysis against fire was carried out. In the analysis, the stiffness and yield strength reduction of the member material at high temperature and the temperature stress of the member were considered, and the damage of the member after the fire resistance limit was evaluated. The results show that the fire resistance design of the critical temperature method and the fire whole process analysis based on the overall structure can basically achieve the design goal of the building structure for anti-progressive collapse against fire. Among them, the large-span composite steel secondary beams are weak components to prevent progressive collapse, and the transfer beams and steel structure nodes need to be strengthened for fire protection.
Keywords: Haikou Twin Towers; fire resistance design; critical temperature method; thermal-solid coupled integral structure model; anti-progressive collapse against fire; component damage assessment