螺旋箍筋约束高强钢筋浆锚搭接单向拉伸试验研究

引用文献:

王卓琳,李向民 ,田坤 ,王明谦. 螺旋箍筋约束高强钢筋浆锚搭接单向拉伸试验研究[J]. 建筑结构,2023,48(08):119-124.

WANG Zhuolin, LI Xiangmin, TIAN Kun, WANG Mingqian. Uniaxial tension experimental study on the grouting-anchoring overlap-joint of high strength steel bar restrained by spiral stirrups[J]. Building Structure,2023,48(08):119-124.

作者:王卓琳,李向民 ,田坤 ,王明谦
单位:上海市建筑科学研究院有限公司上海市工程结构安全重点实验室
摘要:设计制作了9组共78个螺旋箍筋约束高强钢筋浆锚搭接试件,通过单向拉拔试验,研究了其破坏机理以及钢筋强度、混凝土强度、钢筋搭接长度、螺旋箍筋形式等因素对搭接性能的影响。结果表明:未配置螺旋箍筋的浆锚搭接试件主要破坏模式为混凝土的锚固失效开裂,且其承载力和强屈比随钢筋搭接长度的增加逐渐增加;配置螺旋箍筋后,钢筋搭接长度大于0.80lab(lab为钢筋基本锚固长度)时,试件主要破坏模式为钢筋受拉屈服且其极限承载力较稳定;钢筋搭接长度为0.56lab时,试件端部混凝土出现开裂,部分试件的极限承载力显著降低。建议实际工程中钢筋直径为16mm时,螺旋箍筋约束高强钢筋浆锚搭接的搭接长度取0.80lab;其他直径钢筋可参考该搭接长度并经过试验验证后应用。
关键词:高强钢筋;浆锚搭接;螺旋箍筋;搭接长度;单向拉伸;
作者简介:王卓琳,博士,教授级高级工程师,主要从事建筑检测评估与加固改造领域的研究与实践,Email:wzllzw@163.com。李向民,博士,教授级高级工程师,主要从事建筑工业化及绿色化改造领域的研究与实践,Email:lxm_sribs@163.com。
基金:国家重点研发计划项目(2022YFF0609200);上海市科学技术委员会项目(18DZ1205705)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 姜洪斌,张海顺,刘文清,等.预制混凝土结构插入式预留孔灌浆钢筋锚固性能[J].哈尔滨工业大学学报,2011,43(4):28-31,36.
[2] 姜洪斌,张海顺.插入式预留孔灌浆钢筋搭接连接有限元分析[J].低温建筑技术,2010,32(12):33-35.
[3] 马军卫,尹万云,刘守城,等.钢筋约束浆锚搭接连接的试验研究[J].建筑结构,2015,45(2):32-35,79.
[4] 赵培.约束浆锚钢筋搭接连接试验研究[D].哈尔滨:哈尔滨工业大学,2011.
[5] 毛小勇,高奕昕.约束浆锚搭接连接高温性能试验研究[J].建筑结构学报,2020,41(7):117-123.
[6] 金峤,李京龙,高猛,等.含FRP约束环的钢筋搭接连接试验研究[J].建筑结构,2020,50(15):74-79.
[7] 邰晓峰.预制混凝土剪力墙抗震性能试验及约束浆锚搭接极限研究[D].哈尔滨:哈尔滨工业大学,2012.
[8] 杨勇.带竖向结合面预制混凝土剪力墙抗震性能试验研究[D].哈尔滨:哈尔滨工业大学,2011.
[9] 吴涛,刘全威,张磊,等.预制混凝土构件钢筋约束浆锚连接技术发展展望[J].西安建筑科技大学学报(自然科学版),2015,47(6):776-780.
[10] 装配式剪力墙结构设计规程:DB11/1003—2013[S].北京:北京市住房和城乡建设局,2013.
[11] 装配整体式混凝土结构技术规程:DBJ61/T 87—2014 [S].北京:中国建材工业出版社,2014.
[12] 混凝土结构设计规范:GB 50010—2010[S].2015年版.北京:中国建筑工业出版社,2015.
[13] 热处理带肋高强钢筋混凝土结构技术规程:Q/JST S06—2016[S].镇江:江苏天舜金属材料集团有限公司,2016.
[14] 混凝土结构试验方法标准:GB/T 50152—2012[S].北京:中国建筑工业出版社,2012.
Uniaxial tension experimental study on the grouting-anchoring overlap-joint of high strength steel bar restrained by spiral stirrups
WANG Zhuolin, LI Xiangmin, TIAN Kun, WANG Mingqian
(Shanghai Key Laboratory of Engineering Structure Safety, Shanghai Research Institute of Building Sciences Co., Ltd.)
Abstract: Nine groups of seventy-eight specimens of grouting-anchoring overlap-joint of high strength steel bar restrained by spiral stirrups were designed and fabricated. The failure mechanism and the influence of steel bar strength, concrete strength, lapping length of steel bars and spiral stirrup type on the lapping property were investigate by uniaxial tension tests. The results show that the main failure mode of the specimens without spiral stirrups was the anchorage failure and cracking of concrete, and the bearing capacity and ductility ratio increase with the increase of lapping length of steel bars. The main failure mode of specimens restrained by spiral stirrups is steel bar tensile yield, when the lapping length is over 0.80lab(lab is the basic anchorage length of the steel bar), and the bearing capacity of restrained specimens is very stable. When the lapping length of steel bars is 0.56lab, concrete crackes at the end of the restrained specimens, and the bearing capacity of some specimens decrease significantly. It is suggested that when the diameter of steel bar is 16mm in practical engineering, the lapping length of high strength bars should not be less than 0.80lab. The suggested lapping length can be refereed for high strength bars with other diameters, and be verified by the test before application.
Keywords: high strength steel bar; grouting-anchoring overlap-joint; spiral stirrup; lapping length; uniaxial tension
541 0 0