欧阳蓉 徐希 余良刚 贺黄锋. 某多道弱刚性连接的高位收进连体结构设计[J]. 建筑结构,2022,48(08):21-26.

OUYANG Rong XU Xi YU Lianggang HE Huangfeng. Design of a high-income connecting structure with multi-channel weak rigid connection[J]. Building Structure,2022,48(08):21-26.

作者:欧阳蓉 徐希 余良刚 贺黄锋
单位:深圳市市政设计研究院有限公司
摘要:某写字楼公寓项目为两栋功能相同塔楼对称布置的高187.2m的连体建筑,连接体为分别位于第10、19、28层的单层连廊,跨度为39.5m,项目具有连体刚度弱、竖向间距大等特点。从连接形式、连体结构体系、整体结构及连接体抗震性能、连接节点受力、舒适度、温度应力等方面进行分析,得到以下结论:经比选本项目采用刚性连接能够更好地满足建筑功能及建筑立面要求,连体结构采用带水平支撑的X向主钢梁+钢筋桁架楼承板体系;刚度较弱的连接体对塔楼动力特性影响小;弱连接体与塔楼刚接可减小连接体构件内力,可减小截面尺寸,减小施工难度;各连体层温度应力变化基本一致,楼板设计应叠加温度应力。
关键词:连体结构,连体刚度,连接形式,抗震性能,温度应力
作者简介:欧阳蓉,学士,高级工程师,一级注册结构工程师,主要从事结构设计工作,Email:oyroyr@sina.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑结构荷载规范:GB 50009—2012[S].北京:中国建筑工业出版社,2012.
[2] 余永辉,赵宏,金鹤寿,等.某高层大跨度连体结构抗震性能分析与设计[J].建筑结构,2017,47(14):88-93,105.
[3] 甄伟,张磊,张龑华,等.多塔连体高层建筑连接控制方法研究[J].建筑结构,2019,49(18):49-54.
[4] 陈伟军,刘永添,苏艳桃,带连廊高层建筑连接方式设计研究[J].建筑结构学报,2009,30(S1):73-76.
[5] 王维一,黄卓.超高层连体结构设计关键问题研究[J].广东土木与建筑,2017,24(4):19-21.
[6] 建筑工程抗震设防分类标准:GB 50223—2008[S].北京:中国建筑工业出版社,2008.
[7] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[8] 建筑抗震设计规范:GB 50011—2010[S].2016年版.北京:中国建筑工业出版社,2016.
[9] 高层民用建筑钢结构技术规程:JGJ 99—2015[S].北京:中国建筑工业出版社,2016.
Design of a high-income connecting structure with multi-channel weak rigid connection
OUYANG Rong XU Xi YU Lianggang HE Huangfeng
(Shenzhen Municipal Design & Research Institute Co., Ltd.)
Abstract: An office building apartment project is a 187.2 m high connected building with two towers with the same function arranged symmetrically. The connectors are single-layer corridors with a 39.5 m span, located on the 10 th, 19 th, and 28 th floors. It has the characteristics of weak connection stiffness and large vertical spacing. From the analysis of the connection form, the system of the connected structure, the seismic performance of connector and the overall structure, the stress of the connecting node, the comfort level, the temperature stress, etc., the following conclusions show that: the rigid connection in this project can better meet the requirements of the building function and building fa9 ade, the connected structure adopts the X-direction main steel beam with horizontal support + steel truss floor deck system. Connector with weak stiffness has little influence on the dynamic characteristics of the tower. The rigid connection between the weak connector and the tower can reduce the internal force of the connector component, which can reduce the section size and reduce the construction difficulty. The temperature stress change of each connected layer is basically the same, and the internal force of temperature stress should be superimposed on the floor design.
Keywords: connected structure; connection stiffness; connection form; seismic performance; temperature stress
464 0 0
文字:     A-     A+     默认 取消