某水世界乐园场馆大跨度钢结构设计

引用文献:

王强. 某水世界乐园场馆大跨度钢结构设计[J]. 建筑结构,2022,48(08):16-20,98.

WANG Qiang. Large-span steel structure design of a water world stadium[J]. Building Structure,2022,48(08):16-20,98.

作者:王强
单位:上海建筑设计研究院有限公司
摘要:某水世界乐园场馆结构设计中,外部采用大跨度钢结构外壳,与内部混凝土结构相脱离。大跨度结构分下部和上部两部分,通过方案阶段的深入比选,确定了实施的结构体系为Y形柱支撑、以径向桁架作为加劲肋的单层网壳体系;为保证该结构方案的安全性、合理性和经济性,分别进行了结构的振型、应力比、变形、稳定性分析设计,并选取关键节点进行弹塑性有限元分析。分析结果表明,各项指标均满足规范和设计要求,结构在关键构件的性能化分析和非线性稳定性分析中表现良好。对屋盖结构进行分叉柱失效后的抗连续性倒塌分析,结果表明单根分叉柱失效不会引起结构的连续性破坏。
关键词:大跨度钢结构,单层网壳,稳定性分析,抗连续性倒塌
作者简介:王强,学士,高级工程师,一级注册结构工程师,主要从事复杂空间结构设计,Email:wangqiang@aisa.com.cn。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 建筑抗震设计规范:GB 50011—2010 [S].2016年版.北京:中国建筑工业出版社,2016.
[2] 董石麟,罗尧治,赵阳,等.新型空间结构分析、设计与施工[M].北京:人民交通出版社,2006.
[3] 崔家春,周健,杨联萍,等.Y形柱稳定性分析研究[J].建筑结构,2012,42(5):115-118.
[4] 建筑结构荷载规范:GB 50009—2012 [S].北京:中国建筑工业出版社,2012.
[5] 空间网格结构技术规程:JGJ 7—2010 [S].北京:中国建筑工业出版社,2011.
[6] 蔡健,贺盛,姜正荣,等.单层网壳结构稳定性分析方法研究[J].工程力学,2015,32(7):103-110.
[7] 高层民用建筑钢结构技术规程:JGJ 99—2015 [S].北京:中国建筑工业出版社,2016.
[8] 建筑结构抗倒塌设计规范:CECS 392∶2014 [S].北京:中国计划出版社,2015.
Large-span steel structure design of a water world stadium
WANG Qiang
(Shanghai Institute of Architecture Design & Research Co., Ltd.)
Abstract: In the structural design of a water park venue, a large-span steel shell is used on the outside, which is separated from the internal concrete structure. The large-span structure is divided into two parts, the lower part and the upper part. Through in-depth comparison and selection at the plan stage, the implemented structural system was determined, and it is was a single-layer reticulated shell system supported by Y-shaped columns and using radial trusses as stiffeners. In order to ensure the safety, rationality and economy of the structural scheme, the vibration mode, stress ratio, deformation and stability of the structure were carried out respectively. Elastoplastic finite element analysis was carried out for some key joints. The analysis results show that all indicators meet the specifications and design requirements, and the structure performs behave well in the performance analysis and nonlinear stability analysis of key components. The analysis of anti-continuous collapse analysis of the roof structure after the failure of the bifurcation column was done. The results shows that the failure of a single bifurcation column will not cause the continuous failure of the structure.
Keywords: large-span steel structure; single-layer reticulated shell; stability analysis; anti-continuous collapse analysis
473 0 0
文字:     A-     A+     默认 取消