台州方远大饭店双洞式连体复杂结构设计及关键技术

引用文献:

周永明 徐伟斌 高超 戚亚珍 马红莉. 台州方远大饭店双洞式连体复杂结构设计及关键技术[J]. 建筑结构,2022,48(15):58-63.

ZHOU Yongming XU Weibin GAO Chao QI Yazhen MA Hongli. Structural design and key technology of double-hole connected complex structure of Taizhou Fangyuan Hotel[J]. Building Structure,2022,48(15):58-63.

作者:周永明 徐伟斌 高超 戚亚珍 马红莉
单位:浙江省建筑设计研究院
摘要:台州方远大饭店主楼4~6层立面开双洞,洞口净宽分别为35m和13m,净高均为12m,采用新型型钢混凝土组合桁架实现洞口跨越构成整体连体结构。针对该项目的结构特点、难点,阐述了结构薄弱部位与关键技术。探讨了连体结构选型、托柱转换组合桁架及长悬挑组合桁架的选用类型。归纳了罕遇地震下整体结构指标与关键结构构件的损伤情况。论述了转换桁架支承柱及连接节点等关键构件与节点设计。开展了罕遇地震下连体楼板地震应力分析与连体结构施工模拟专项分析。分析了超长连体结构温差效应,采用了新型诱导缝等关键技术来减弱温差效应。目前项目已交付使用,满足建筑造型及使用功能要求,验证了分析研究及设计对策的可行性。
关键词:双洞连体结构;托柱转换组合桁架;抗震性能分析;施工模拟;超长连体结构
作者简介:周永明,硕士,正高级工程师,主要从事超高层结构和复杂结构设计工作,Email:9764zym@sina.com。
基金:浙江省建筑设计研究院科研项目(2021K06)。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 徐培福,傅学怡,王翠坤,等.复杂高层建筑结构设计[M].北京:中国建筑工业出版社,2005.
[2] 钱昆.镜湖梅山广场南区酒店双向高位连体框架一支撑结构设计[J].建筑结构,2021,51(13):28-36.
[3] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[4] 组合结构设计规范:JGJ 138—2016[S].北京:中国建筑工业出版社,2016.
[5] 张然,吴中群,沈凯霞,等.重庆地产大厦双塔连体结构设计[J].建筑结构,2013,43(17):90-95.
[6] 黄明波.东方国际商务中心复杂连体超限高层结构抗震设计[J].建筑结构,2021,51(15):62-67.
[7] 赵攀宇,吴勇,战祖弘,等.带薄弱连体的超高层结构抗震性能设计[J].建筑结构,2021,51(15):68-75.
[8] 建筑结构荷载规范:GB 50009—2012[S].北京:中国建筑工业出版社,2012.
[9] 李涛,梁汝鸣,和西良,等.温度诱导缝对超长结构温度应力的影响研究[J].建筑结构,2022,52(3):13-18.
[10] 吴林,程睿,崔佳,等.重庆国泰艺术中心大跨度转换钢桁架施工过程模拟分析[J].钢结构,2012(增刊):803-808.
Structural design and key technology of double-hole connected complex structure of Taizhou Fangyuan Hotel
ZHOU Yongming XU Weibin GAO Chao QI Yazhen MA Hongli
(Zhejiang Province Institute of Architectural Design and Research)
Abstract: The main building of Taizhou Fangyuan Hotel has double holes on the façade of the 4th to 6th floors. The net width of double holes is 35 m and 13 m respectively, and the net height are both 12 m. The new type steel reinforced concrete composite trusses are used to realize the span of the openings to form an integral connecting structure. In view of the structural characteristics and difficulties of the project, the weak parts and key technologies of the structure were expounded. The selection of connected structure, column transfer composite truss and long cantilever composite truss were discussed. The index of overall structure and the damage of key structural components under rare earthquake were summarized. The design of key components and joints such as the supporting columns and connecting joints of the transfer truss was described. the seismic stress analysis of conjoined slabs under rare earthquake and special analysis of construction simulation of connected structure were conducted. The temperature effect of ultra-long connected structure was analyzed and key technologies such as new inducing joint were used to reduce temperature effect. At present the project has been put into use and it meets the requirements of architectural modeling and use function, which verifies the feasibility of analysis and design countermeasures.
Keywords: double-hole connected structure; column transfer composite truss; seismic performance analysis; construction simulation analysis; ultra-long connected structure
280 0 0
文字:     A-     A+     默认 取消