变工况下地铁屏蔽门风压特性实测研究
摘要:针对屏蔽门风压问题,通过改变车站公共区机械送排风系统、轨行区上下排热系统和活塞风井通风系统得到8种组合工况,对列车正常运行下屏蔽门风压进行测试。结果表明:在车站公共区机械送排风系统变工况下,不同位置屏蔽门同一时刻承受的风压极值最大相差近50%,不能作为调控屏蔽门风压的有效手段;轨行区上下排热系统变工况下,开启上排热能降低中部屏蔽门的最大正压值,但对两侧屏蔽门的效果并不好,因此轨行区上排热系统不能作为调控屏蔽门风压的有效手段;双活塞风井连通风阀变工况下,开启连通风阀能有效降低屏蔽门风压值,正压峰值最大能降低88.3%,负压峰值最大能降低50%。
关键词:地铁屏蔽门风压变工况送排风上下排热活塞风井连通风阀
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
限时优惠福利:领取VIP会员
全年期刊、VIP视频免费!
全年期刊、VIP视频免费!
参考文献[1] 韩二文.地铁列车活塞风压导致的站台屏蔽门开关故障分析及改进措施[J].城市轨道交通研究,2018,21(8):142- 145.
[2] 罗燕萍,李林林,饶美婉.高密度行车时隧道风压对屏蔽门开关的影响[J].城市轨道交通研究,2015,18(4):42- 46.
[3] 陈治平.论活塞风对屏蔽门运行造成的影响[J].住宅与房地产,2018(6):219- 220.
[4] 黄建林.上海轨道交通车站屏蔽门承压测试研究与分析[J].地下工程与隧道,2017(2):42- 44.
[5] 邓国勇.谈隧道风压对屏蔽门关门的影响及应对措施[J].华东科技(学术版),2017(5):342- 343.
[2] 罗燕萍,李林林,饶美婉.高密度行车时隧道风压对屏蔽门开关的影响[J].城市轨道交通研究,2015,18(4):42- 46.
[3] 陈治平.论活塞风对屏蔽门运行造成的影响[J].住宅与房地产,2018(6):219- 220.
[4] 黄建林.上海轨道交通车站屏蔽门承压测试研究与分析[J].地下工程与隧道,2017(2):42- 44.
[5] 邓国勇.谈隧道风压对屏蔽门关门的影响及应对措施[J].华东科技(学术版),2017(5):342- 343.
Experimental study on wind pressure characteristics of metro platform screen doors under variable conditions
Abstract: Aiming at the wind pressure problem of the platform screen door, by changing the eight operating conditions of the mechanical air supply and exhaust system in the public area of the station, the upper and lower heat exhaust systems in the track area, and the ventilation system of the piston air shaft, the wind pressure of the platform screen door under normal train operation is tested. The results show that under the variable conditions of the mechanical air supply and exhaust system in the public area of the station, the maximum difference of wind pressure experienced by the platform screen doors in different positions at the same time is nearly 50%, which cannot be used as an effective means to control the wind pressure of the platform screen door. Under the variable conditions of the upper and lower heat exhaust systems in the track area, opening the upper heat exhaust system can reduce the maximum positive pressure value of the middle platform screen door, but the effect is not good for both sides of the platform screen door, so the upper heat exhaust system in the track area cannot be used as an effective means to control the wind pressure of the platform screen door. Under the variable conditions of the connecting air valve of the double-piston air shaft, opening the connecting air valve can effectively reduce the wind pressure value of the platform screen door, the peak value of positive pressure can be reduced by 88.3%, and the peak value of negative pressure can be reduced by 50%.
Keywords: metro; platform screen door; wind pressure; variable condition; air supply and exhaust; upper and lower heat exhaust; piston air shaft; connecting air valve;