多塔高位转换结构设计研究

引用文献:

骆年红 黄用军. 多塔高位转换结构设计研究[J]. 建筑结构,2022,48(17):72-77,44.

LUO Nianhong HUANG Yongjun. Design and research of multi-tower high-position transfer structure[J]. Building Structure,2022,48(17):72-77,44.

作者:骆年红 黄用军
单位:深圳市欧博工程设计顾问有限公司
摘要:1栋多塔高位转换结构包括1栋193.05m高的住宅、1栋155.9m高的保障房及下部42.6m高的裙房,塔楼转换层均位于第9层,为部分框支剪力墙结构。结构存在扭转不规则、凹凸不规则、尺寸突变、高位转换等不规则项,采用基于性能的抗震设计方法对结构进行整体计算,重点分析了高阶振型对构件内力的影响,单向少墙体系的墙肢平面外承载力,并对转换层进行实体有限元分析以校核框支梁的内力和应力分布,给出了型钢偏心连接节点的应力分布云图。分析结果表明,结构各项指标均满足设计规范要求,抗震性能能够达到设定的性能目标C,在分析的基础上结合结构特点提出了针对性的加强措施。
关键词:多塔;高位转换;凹凸不规则;尺寸突变;高阶振型;单向少墙
作者简介:骆年红,硕士,高级工程师,一级注册结构工程师,主要从事超高层及复杂建筑的结构设计工作,Email:lnhmaster@163.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 深圳市罗湖区笋岗街道城建梅园片区城市更新单元05地块1栋结构超限审查报告[R].深圳:深圳市欧博工程设计顾问有限公司,2020.
[2] 深圳市罗湖区笋岗街道城建梅园片区城市更新单元项目主体结构风洞试验报告[R].广州:广东省建筑科学研究院集团股份有限公司风工程研究中心,2020.
[3] 徐培福,王翠坤,郝锐坤,等.转换层设置高度对框支剪力墙结构抗震性能的影响[J].建筑结构,2000,30(1):38-42.
[4] 超限高层建筑工程抗震设防专项审查技术要点:建质[2015]67号[A].北京:中华人民共和国住房和城乡建设部,2015.
[5] 高层建筑混凝土结构技术规程:JGJ 3—2010 [S].北京:中国建筑工业出版社,2011.
[6] 荣维生,王亚勇.层间位移角比在高层转换结构抗震设计中的应用[J].建筑结构,2007,37(8):1-4.
[7] 建筑工程风洞试验方法标准:JGJ/T 338—2014[S].北京:中国建筑工业出版社,2015.
[8] 魏琏,谭伟,王文涛,等.X向少墙时Y向剪力墙结构墙体面外抗震设计[J].建筑结构,2017,47(1):28-32.
[9] 魏琏,王森,曾庆立,等.一向少墙的高层钢筋混凝土结构的结构体系研究[J].建筑结构,2017,47(1):23-27.
[10] 林斯嘉,赖洪涛.贵阳未来方舟G7框支转换结构分析与设计[J].建筑结构,2019,49(20):34-39.
Design and research of multi-tower high-position transfer structure
LUO Nianhong HUANG Yongjun
(Shenzhen AUBE Architectural Engineering Design Co.,Ltd.)
Abstract: A multi-tower high-position transfer structure includes a 193.05 m high residential building, a 155.9 m high security house and a lower 42.6 m high podium. The tower transfer floors are located on the 9 th floor and are partially frame-supported shear wall structures. The structure has irregularities such as torsional irregularity, concave and convex irregularities, sudden size mutation, and high-position transfer. The overall calculation of the structure was carried out by using the performance-based seismic design method. The influence of high-order vibration mode on the internal force of the member and the out-of-plane bearing capacity of the wall limb of the structural system with few-shear-walls in one direction were analyzed. The solid finite element analysis of the transfer layer was carried out to check the internal force and stress distribution of the frame-supported beam, and the stress distribution cloud diagram of the eccentric connection of section steel was given. The analysis results show that all the indexes of the structure meet the requirements of the design code, and the seismic performance can reach the set performance target C. Based on the analysis, the corresponding strengthening measures were proposed in combination with the structural characteristics.
Keywords: multi-towel; high-position transfer; concave and convex irregularity; size mutation; high-order vibration mode; few-shear-walls in one direction
345 0 0
文字:     A-     A+     默认 取消