带穿层柱框架结构设计的若干问题探讨及建议

引用文献:

方义庆. 带穿层柱框架结构设计的若干问题探讨及建议[J]. 建筑结构,2022,48(12):17-24.

FANG Yiqing. Discussion and suggestion on several issues about structural design of frame structures with cross-story column[J]. Building Structure,2022,48(12):17-24.

作者:方义庆
单位:安徽五维建筑规划设计有限公司
摘要:结合带穿层柱框架结构的特点,分析了目前计算带穿层柱框架结构的楼层侧向刚度、楼层受剪承载力比、扭转位移比时存在的问题,并给出了计算分析建议与方法。提出一种穿层柱高度范围内等效侧向刚度计算方法,解决了因夹层难以量化定义而带来的层侧向刚度比计算问题。以一中间楼层带穿层柱的12层框架结构为例,对水平荷载作用下的带穿层柱框架结构传力路径进行分析。结果表明,穿层柱和非穿层柱在穿层柱顶、底楼盖位置均存在剪力突变,该位置楼板起到传递水平力作用。分析了不同梁板缺失范围对带穿层柱框架结构的楼层侧向刚度比、扭转位移比、楼层受剪承载力比值的影响。结果表明,随着梁板缺失范围增加,层概念软件默认算法的误差越大,会误判结构的扭转规则性、竖向规则性,建议按照本文建议方法复核。
关键词:穿层柱;传力路径;扭转位移比;楼层侧向刚度;楼层受剪承载力;夹层
作者简介:方义庆,硕士,高级工程师,一级注册结构工程师,主要从事建筑结构设计与研究,Email:121596026@qq.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 超限高层建筑工程抗震设防专项审查技术要点:建质[2015]67号[A].北京:中华人民共和国住房和城乡建设部,2015.
[2] 建筑抗震设计规范:GB 50011—2001[S].北京:中国建筑工业出版社,2001.
[3] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[4] 建筑抗震设计规范:GB 50011—2010[S].北京:中国建筑工业出版社,2010.
[5] 建筑抗震设计规程:DGJ 08-9—2013[S].上海:上海城乡建设和交通委员会,2013.
[6] 高层建筑混凝土结构技术规程:DBJ/T 15-92—2021[S].广州:广东省住房和城乡建设厅,2021.
[7] 高层建筑混凝土结构技术规程:SJG 98—2021[S].深圳:深圳市住房和建设局,2021.
[8] 唐曹明,徐培福,徐自国,等.钢筋混凝土框架结构楼层刚度比限制方法研究[J].土木工程学报,2009,42(12):128-134.
[9] 四川省超限高层建筑抗震设计图示:川2020G145-TY[S].成都:四川省建筑标准设计办公室,2020.
[10] 建筑抗震鉴定标准:GB 50023—2009[S].北京:中国建筑工业出版社,2009.
[11] 建筑抗震设计规范:GB 50011—2010[S].2016年版.北京:中国建筑工业出版社,2016.
[12] YJK用户手册及技术条件[M].北京:北京盈建科软件股份有限公司,2020.
[13] 魏琏,王森.扭转不规则建筑竖向构件考虑扭矩影响的抗震验算方法[J].建筑结构,2006,36(7):8-10,20.
Discussion and suggestion on several issues about structural design of frame structures with cross-story column
FANG Yiqing
(Anhui Wuwei Architectural Design and Urban Planning Co., Ltd.)
Abstract: Combined with the characteristics of frame structures with cross-story columns, the problems existing in the calculation of lateral stiffness ratio, story shear capacity ratio and torsional displacement ratio were analyzed, and the suggestions and methods for calculation and analysis were given. A method for calculating the equivalent lateral stiffness within height range of cross-story column was proposed to solve the calculation problem of story lateral stiffness ratio caused by the difficulty of quantifying the definition of mezzanine. Taking a 12-story frame structure with cross-story columns in the middle floor as an example, the load path of the frame structure with cross-story columns under the action of horizontal load was analyzed. The results show that both the cross-story column and the frame column have shear mutation at the location of top and bottom floors of the cross-story column, and the floor plays the role of horizontal load path at this position. The effects of different beam-slab missing ranges on the story lateral stiffness ratio, torsional displacement ratio, and story shear bearing capacity ratio of the frame structure with cross-story columns were analyzed. The results show that with the increase of the beam-slab missing ranges, the error of the default algorithm of story concept software becomes larger, which will misjudge the torsional regularity and vertical regularity of the structure. It is suggested to check the structure according to the proposed method in this paper.
Keywords: cross-story column; load path; torsional displacement ratio; story lateral stiffness; story shear capacity; mezzanine