单位:北京三磊建筑设计有限公司
摘要:对于框架-核心筒超高层结构而言,和传统的有梁楼盖相比,外框与核心筒之间采用不设明梁的平板楼盖体系在降低建筑层高、改善建筑布置及提高施工效率等方面具有较为明显的优势,但由于平板楼盖体系节点抗震性能相对较弱,目前在高烈度区超高层结构中的应用还很少。以北京通州某公寓主楼为例,针对框架-核心筒平板楼盖体系结构特点,重点探讨了从结构体系认定、结构选型、结构布置、设计难点、构造措施及整体计算等方面对塔楼所采取的加强措施。在小震反应谱分析基础上,补充进行了中震下构件承载力分析及大震下静力弹塑性分析。结果表明,结构各项指标均比较理想,整体设计满足结构安全要求。
关键词:平板楼盖体系,超高层结构,框架-核心筒,有梁楼盖,高烈度区
作者简介:李明雨,硕士,高级工程师,一级注册结构工程师,主要从事建筑结构设计,Email:66295423@qq.com。
基金:
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
[2] 周威,许名鑫.带无梁楼盖的框架-核心筒结构设计中三个问题分析[J].结构工程师,2009,25(3):7-11.
[3] 程懋堃.关于板柱结构的适用高度[J].建筑结构学报,2003,24(S1):1-6.
[4] 戴国莹,徐培福,柯长华,等.通州运河核心区05地块公寓楼抗震设计意见[R].北京:北京三磊建筑设计有限公司,2016.
[5] 马凯.中震作用下超高层结构核心筒墙肢拉应力分析与设计[J].建筑结构,2016,46(17):84-87.
Flat-plate floor system application in a super high-rise structure
LI Mingyu WANG Zhijun
(Sun Lay Architectural Design Institute,Beijing)
Abstract: For frame-core tube super high-rise structure, compared with beam-plate floor system, flat-plate floor system without exposed beams between the outer frame and the core tube has obvious advantages in reducing the floor height of storey, improving architectural layout and construction efficiency. However, its application is less in high earthquake intensity regions super high-rise building for its poor seismic performance. Taking a main apartment building in Tongzhou, Beijing as an example, according to the structure characteristic of flat-plate floor system, strengthening measures were carried out, including the structural system identification, structural system selection, structural layout, design difficulty, structural measure and overall calculations. On the basis of response spectrum analysis under the frequent earthquake, the bearing capacity of components analysis under fortification intensity earthquake and the static elastic-plastic analysis under rare earthquake were conducted. Results show that structural indicators are ideal and the overall structural design satisfies safety requirement.
Keywords: flat-plate floor system; super high-rise structure; frame-core tube; beam-plate floor system; high earthquake intensity region