大跨度平板-剪力墙结构体系可行性研究

引用文献:

朱礼敏 王欢欢 田春雨 胡兰英 王爱志. 大跨度平板-剪力墙结构体系可行性研究[J]. 建筑结构,2022,48(3):43-50,115.

ZHU Limin WANG Huanhuan TIAN Chunyu HU Lanying WANG Aizhi. Feasibility study of shear wall structure system with large span flat slab[J]. Building Structure,2022,48(3):43-50,115.

作者:朱礼敏 王欢欢 田春雨 胡兰英 王爱志
单位:中国建筑科学研究院有限公司 广东建星建造集团有限公司
摘要:选取两个已建的工程实例按照平板-剪力墙结构布置,首先对其进行多遇地震和风荷载作用下的弹性分析,完成结构设计;然后进行罕遇地震下的弹塑性时程分析,研究其抗震性能及破坏形态;最后对平板-剪力墙体系的经济性进行了分析。结果表明,在多遇地震和风荷载作用下,平板-剪力墙体系的整体指标均满足《高层建筑混凝土结构技术规程》(JGJ 3—2010)的要求,构件验算也满足承载力要求,能够实现“小震不坏”的设防目标;在罕遇地震作用下,平板-剪力墙体系的层间位移角满足规范限值1/120的要求,墙体和楼板的损伤均不大,能够实现“大震不倒”的设防目标;平板-剪力墙体系的材料用量与传统剪力墙体系相比略低或持平。在此基础上,对平板-剪力墙体系的板厚取值、板内暗梁设置等提出了建议,可为今后工程应用提供参考。
关键词:大跨度平板-剪力墙体系,可行性研究,受力性能,经济性
作者简介:朱礼敏,博士,研究员,一级注册结构工程师,主要从事复杂建筑结构体系的研究,Email:zhulimin@cabrtech.com。
基金:广东省工程建设地方标准《大跨度平板-剪力墙结构技术规程》编制项目。
尊敬的用户,本篇文章需要2元,点击支付交费后阅读
参考文献[1] 南建林,黄鼎业.大开间预应力混凝土平板住宅的结构体系[J].建筑科学,2010,26(5):22-27.
[2] 秦力.中高层住宅结构体系优化设计研究[D].大连:大连理工大学,2003.
[3] 邵旭斌.大空间住宅剪力墙出平面承载力研究[D].南京:河海大学,2005.
[4] 范卫东,任建淼,杨永葆.大开间剪力墙结构在保障性住房中的应用[J].住宅科技,2019(4):22-25.
[5] 王淑英.高层住宅大开间剪力墙结构设计[J].福建建设科技,2002(1):17-18.
[6] 桂军.板-墙体系结构抗震性能分析[D].昆明:昆明理工大学,2015.
[7] 付章.板墙体系静力试验设计和工程技术经济分析[D].昆明:昆明理工大学,2014.
[8] 建筑抗震设计规范:GB 50011—2010[S].北京:中国建筑工业出版社,2010.
[9] 混凝土结构设计规范:GB 50010—2010[S].北京:中国建筑工业出版社,2011.
[10] 高层建筑混凝土结构技术规程:JGJ 3—2010[S].北京:中国建筑工业出版社,2011.
Feasibility study of shear wall structure system with large span flat slab
ZHU Limin WANG Huanhuan TIAN Chunyu HU Lanying WANG Aizhi
(China Academy of Building Research Guangdong Constar Construction Group Co., Ltd.)
Abstract: Two built engineering examples were selected according to the layout of the shear wall structure with flat slab. Firstly, the elastic analysis under the frequent earthquake and wind load was carried out to complete the structural design. Then, the elastoplastic time-history analysis was completed under rare earthquakes to study its seismic performance and failure modes. Finally, the economy of the shear wall system with flat slab was analyzed. The results show that under the frequent earthquake and wind load, the whole index of the shear wall system with flat slab meets the requirements in Technical specification for concrete structures of tall building(JGJ 3—2010), and the members checking also meets the requirements of bearing capacity, which can achieve the fortification goal of “no damage during frequent earthquake”; Under the rare earthquake, the inter-story drift angle of the shear wall system with flat slab meets the standard limit 1/120, and the damage of the wall and slab is not serious, which can achieve the fortification goal of “no collapse during rare earthquake”; Compared with traditional shear wall systems, the material amount used in the shear wall system with flat slab is slightly lower or the same. On the basis of the above, some suggestions were put forward for the slab thickness and setting the hidden beam in the slab of the shear wall system with flat slab, which will provide references for the future engineering application.
Keywords: shear wall system with large span flat slab; feasibility study; mechanical behavior; economy